GoodWe ES Uniq GW10K-ES-C10 10KW Hybrid Solar Inverter
The GoodWe ES Uniq GW10K-ES-C10 is a state-of-the-art single-phase hybrid inverter, specifically engineered for residential energy storage systems. Designed to support modern solar solutions, it offers unmatched flexibility and scalability with advanced safety features and robust performance
Key Features
- Versatile Power Range: Supports 8KW, 10KW, and 12KW capacities, catering to a variety of energy demands.
- 200% Oversizing & Overload Capacity: Handles up to 200% module oversizing and load overload for reliable performance during peak consumption.
- Seamless Generator Management: Facilitates energy storage from generators for added reliability in hybrid setups.
- Parallel Operation Support: Allows parallel connection of up to 16 inverters for scalable on-grid and off-grid configurations.
- Compatible with 182mm Modules: Ensures efficient energy harvesting with cutting-edge solar module technology.
- Advanced PV String Monitoring: Enables real-time tracking of solar array performance for enhanced system management.
Safety Features
- Anti-Islanding Protection: Safeguards the grid and inverter in the event of disconnection.
- Input Reverse Polarity Protection: Prevents damage caused by incorrect solar panel wiring.
- Insulation Resistor Detection: Monitors system insulation for increased safety.
- Residual Current Monitoring Unit (RCMU): Detects and addresses electrical leakage issues.
- Output Over Current Protection: Shields the inverter and connected devices from power surges.
- Output Short Protection: Ensures safety during unexpected faults.
The GoodWe ES Uniq GW10K-ES-C10 delivers a robust, scalable, and secure energy storage solution, making it an excellent choice for modern residential solar systems with growing energy requirements.
SPECIFICATIONS
Technical Data | GW10K-ES-C10 |
Battery Input Data | |
Battery Type | Li-Ion Lead-acid |
Nominal Battery Voltage (V) | 48 |
Battery Voltage Range (V). | 40~60 |
Max. Continuous Charging Current (A) | 200 |
Max. Continuous Discharging Current (A)”1 | 200 (220 at 10min) |
Max. Charging Power (W) | 10000 |
Max. Discharging Power (W) | 11000 |
PV String Input Data | |
Max. Input Power (W) | 20000 |
Max. Input Voltage (V) | 600 |
MPPT Operating Voltage Range (V) | 60 ~50 |
Start-up Voltage (V) | 58 |
Nominal Input Voltage (V) | 360 |
Max. Input Current per MPPT (A)*2 | 32/32 |
Max. Short Circuit Current per MPPT (A) | 48/48 |
Number of MPP Trackers | 2 |
Number of Strings per MPPT | 2/2 |
AC Output Data (On-grid) | |
Nominal Output Power (W) | 10000 |
Nominal Apparent Power Output to Utility Grid (VA) | 10000 |
Max. AC Active Power (W)3 | 11000 |
Max. Apparent Power Output to Utility Grid (VA)*3 | 11000 |
Max. Apparent Power from Utility Grid (VA) | 16500 |
Nominal Output Voltage (V) | 220/230/240 |
Output Voltage Range (V) | 170~280 |
Nominal AC Grid Frequency (Hz) | 50/60 |
AC Grid Frequency Range (Hz) | 45~55/55~65 |
Max. AC Current Output to Utility Grid (A) | 50 |
Max. AC Current From Utility Grid (A) | 75 |
Power Factor | (Adjustable from 0.8 leading to 0.8 lagging) |
Max. Total Harmonic Distortion | <3% |
AC Output Data (Back-up) | |
Back-up Nominal Apparent Power (VA) | 10000 |
Max. Output Apparent Power (VA) | 11000 (20000 at 10s) |
Max. Output Current (A) | 50 |
Nominal Output Voltage (V) | 220/230/240 |
Nominal Output Frequency (Hz) | 50/60 |
Output THDV (@Linear Load) | <3% |
AC Data (Generator) | |
Nominal Apparent Power from AC generator (VA) | 10000 |
Max. Apparent Power from AC generator (VA) | 12000 |
Nominal Intput Voltage (V) | 220/230/240 |
Input Voltage Range (V) | 170~280 |
Nominal AC generator Frequency (Hz) | 50/60 |
AC generator Frequency Range (Hz) | 45~55/55~65 |
Max. AC Current From AC generator (A) | 54.5 |
Nominal AC Current From AC generator (A) | 45.5 43.5/41.7 |
Nominal Input Current (A) | 45.543.541.7 |
Efficiency | |
Max. Efficiency | 97.6% |
European Efficiency | 96.2% |
Max. Battery to AC Efficiency | 95.5% |
MPPT Efficiency | 99.9% |
Protection | |
PV String Current Monitoring | Integrated |
PV Insulation Resistance Detection | Integrated |
Residual Current Monitoring | Integrated |
PV Reverse Polarity Protection | Integrated |
Anti-islanding Protection | Integrated |
AC Overcurrent Protection. | Integrated |
AC Short Circuit Protection | Integrated |
AC Overvoltage Protection. | Integrated |
DC Switch | Integrated |
DC Surge Protection | Type III |
AC Surge Protection | Type III |
AFCI | Optional |
Remote Shutdown | Integrated |
General Data | |
Operating Temperature Range (°C) | -35 ~ +60 |
Relative Humidity | 0-95% |
Max. Operating Altitude (m) | 3000 |
Cooling Method | Smart Fan Cooling |
User Interface | LED, WLAN + APP |
Communication with BMS | CAN |
Communication with Meter | RS485 |
Communication with Portal | LAN/WiFi |
Weight (kg) | 29 |
Dimension (W x H x D mm) | 560 x 444.5 x 226 |
Topology | Non-isolated |
Self-consumption at Night (W) | <10 |
Ingress Protection Rating | IP66 |
Mounting Method | Wall Mounted |